01103 HT Chamber Liner Attachment

Home PROFILE DIRECT VENT OIL BOILERS OUTDOOR OS GAS BOILERS POOL HEATERS MANUALS WARRANTY BULLETINS CONTACTS

 

1. HT Series chamber liners are first secured in place with a high temperature adhesive.

2. A 1/2" x 3/4" stainless steel tab stop is them welded in place, positioned at six o'clock on the open end or outlet side of the chamber as a mechanical stop. (The tab can be bent to allow for future replacement as necessary.)

Note: Early models did not have a stainless steel tab.  If the unit does not have a stainless steel tab, fasten in place by placing a small amount of Furnace Cement (about 1/2" high x 1" diameter) at the open or outlet side of the chamber in the six o'clock position. This is the same location as we presently position the stainless steel mechanical stop.