 | FIRING RATE 0.85 to 1.50 GPH - Allows the installer to size the boiler
more closely to the home heating needs for greater efficiency. The lowest firing rate,
0.85-87,000 BTU, is necessary for many well insulated homes where the heat loss is
minimal.
|
 | COMBUSTION CHAMBER - 1" thick pyrolite ceramic fiber material.
Fast warm-up - glows to incandescence in 11-17 seconds. Large diameter allows brushing
flue passages without punching through chamber.
|
 | PUMP PRESSURE - The S-Series operates at 140 PSI pump pressure for
better fuel atomization, thereby having the ability to tolerate fuel oil with heavy ends.
|
 | IGNITION SYSTEM - The S-Series is standard with a state-of-the-art,
solid state ignition system, making it more tolerant to low voltage or voltage
fluctuations.
|
 | INTEGRATED IGNITION.
|
 | ELECTRONIC DELAY with Solenoid Valve "clean-cut" Fuel
Pump.
|
 | WATER CONTENT - Compared to other dry base boilers, the S-Series has
exceptional water content. The first size has 16 gallons of water. High water volume and
placement of the coil in the hottest part of the boiler allows for maximum coil
performance.
|
 | EFFICIENCIES UP TO 86% AFUE - The unique tube design of the S-Series
boiler heat exchanger slows the flue gases, allowing for more effective heat transfer
without the need for extreme baffling often seen in other vertical tube boilers.
|
 | LIFETIME LIMITED WARRANTY- Unlike other
pro-rated warranties that often cover a small percentage of the cost of a new boiler after
the 15th or 20th year, Thermo-Dynamics boiler replacement are never more than 50% of the
replacement list price list.
|
 | ASME CONSTRUCTED AND IBR RATED- Each boiler is constructed and
hydrostatically tested in accordance with ASME Boiler Code. The capacity and efficiency
are rated in accordance with the standards of the Institute of Boiler and Radiator
Manufacturers (IBR).
|
 | STANDARD FEATURES- The following built-in features found in all
Thermo-Dynamics boilers increase the longevity of the boiler and make the unit easier to
service, ensuring maximum efficiency and performance for the life of the boiler:
 | Built-in "Air Scoop" purges air from the system providing a
quiet, trouble free hot water heating system without the use of external devices.
|
 | Extended Flange Coil is away from the boiler for easy accessibility.
The use of ribbed neck carriage bolts eliminates the problems encountered when a weld stud
is broken during servicing. The large coil plate allows for a greater gasket sealing area.
|
 | Extended weld fittings of SA106-Schedule 80 seamless pipe extend
beyond the jacket and allow the service technician or homeowner to see small leaks
that, if undetected, could later damage the boiler shell and void the warranty.
|
 | Easy cleaning and maintenance accessibility to combustion areas and the
open tubes make it easy for the service technician to thoroughly clean the boiler. No
tight, pin-type passage ways with "hidden nooks and crannies", making a thorough
cleaning impossible. A well-maintained boiler continues to perform at higher efficiency
and is less likely to develop service problems.
|
|


STANDARD EQUIPMENT
|
ASME Code Boiler
|
3450 rpm Hi Speed Flame Retention Oil Burner
|
Flush Jacket
|
"Clean-Cut" Fuel Pump
|
Insulation
|
Interrupted Ignition Primary
|
Ceramic Fiber combustion Chamber
|
Electronic Delay /Valve
|
Altitude, Temperature & Pressure Gauge
|
Hydronic Triple Aquastat Relay
|
ASME Relief Valve
|
007 Circulator or Equivalent (mounted)
|
Tankless Heater - 3 gpm
|
Brass Boiler Drain Valve
|
Factory Assembled, Wired and Packaged
|
|
Note: S-125/135/150 package
boilers shipped w/3-nozzles/firing rates - 1.25 GPH nozzle installed at factory.
|

MODELS
|
S 85
|
S 100
|
S 110
|
***S 125
|
***S 135
|
*** S 150
|
IBR Firing Rate G.P.H. (Max.)
|
.85
|
1.00
|
1.10
|
***1.25
|
***1.35
|
***1.50
|
Nozzle Size
|
.65
|
.75
|
.85
|
1.00
|
1.10
|
1.25
|
IBR Input (BTU/HR)
|
119,000
|
140,000
|
154,000
|
175,000
|
189,000
|
210,000
|
IBR Heating Capacity (BTU/HR)*
|
101,000
|
118,000
|
130,000
|
149,000
|
159,000
|
175,000
|
IBR Net Rating (BTU/HR)
|
88,000
|
103,000
|
113,000
|
130,000
|
138,000
|
152,000
|
Chimney Size
|
8X8X15
|
8X8X15
|
8X8X15
|
8X8X15
|
8X8X15
|
8X8X15
|
Draft Over Fire (Negative)
|
.02
|
.02
|
.02
|
.02
|
.02
|
.02
|
Water Content (Gal.)
|
16
|
15-1/2
|
14
|
14
|
14
|
14
|
Domestic Coil Capacity**
|
3.5
|
3.5
|
3.5
|
3.5
|
3.5
|
3.5
|
A- Jacket Height
|
38-1/2"
|
38-1/2"
|
38-1/2"
|
38-1/2"
|
38-1/2"
|
38-1/2"
|
B- Jacket Width
|
21-1/4"
|
21-1/4"
|
21-1/4"
|
21-1/4"
|
21-1/4"
|
21-1/4"31"
|
C- Coil Supply Height
|
31"
|
31"
|
31"
|
31"
|
31"
|
31"
|
D- Hydronic Return Height
|
22"
|
22"
|
22"
|
22"
|
22"
|
22"
|
E- Jacket Length
|
21-1/4"
|
21-1/4"
|
21-1/4"
|
21-1/4"
|
21-1/4"
|
21-1/4"
|
F- Alt. Hydronic Return
|
22"
|
22"
|
22"
|
22"
|
22"
|
22"
|
G- Hydronic Supply Height
|
36"
|
36"
|
36"
|
36"
|
36"
|
36"
|
H- Flue Pipe Diameter
|
6"
|
6"
|
6"
|
6"
|
6"
|
6"
|
I- Relief Valve Height
|
33-1/2"
|
33-1/2"
|
33-1/2"
|
33-1/2"
|
33-1/2"
|
33-1/2"
|
Shipping Weight (Approx.)
|
320
|
325
|
330
|
345
|
350
|
360
|
Hydronic Supply Tapping
|
1-1/4"
|
1-1/4"
|
1-1/4"
|
1-1/4"
|
1-1/4"
|
1-1/4"
|
Hydronic Return Tappings
|
2-1 1/4"
|
2-1 1/4"
|
2-1 1/4"
|
2-1 1/4"
|
2-1 1/4"
|
2-1 1/4"
|
AFUE
|
84.3
|
84.2
|
84.0
|
84.6
|
84.0
|
83.0
|
* Based on D.O.E. Test Procedure
|
** Coil capacity based on 5 min. draw. 5 min. waiting
period.
|
*** S-125/135/150- Blended Firing Rates.
|

 |